Product information
product name: Benzene gas alarm
product brand: Skyeaglee
Product number: SK-600-C6H6
Measurement object: Benzene gas in the air
product description

Gas introduction:

Benzene is a kind of hydrocarbon which is the simplest aromatic hydrocarbon. It is a sweet, flammable, colorless and transparent liquid with carcinogenic toxicity at normal temperature, and has a strong aromatic odor. It is hardly soluble in water, easily soluble in organic solvents, and itself can be used as an organic solvent. The ring system of benzene is called benzene ring. The structure of benzene ring after removing a hydrogen atom is called phenyl, which is represented by Ph. Therefore, the chemical formula of benzene can also be written as PhH. Benzene is a basic petrochemical raw material, and its output and production technology level are one of the signs of a country's petrochemical development level.

SK-600-C6H6 on-line benzene gas alarm can perform continuous online monitoring for 24 hours, on-site display of concentration and exceeding standard sound and light alarm, and remote data transmission. Adopt 2.5-inch high-definition color screen to display the concentration in real time. According to different detection gases, select the best brands of the current industry's electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoion principle gas sensors, Swiss high-precision capacitive digital temperature and humidity sensors SK-600-C6H6's advanced circuit design and mature kernel algorithm processing have obtained a number of software work patents and appearance patents, thus giving birth to the industry's leading new generation of multifunctional fixed online benzene gas detection alarms. SK-600-C6H6 can detect the gas concentration in the pipeline or confined space, the atmospheric environment can also detect the gas leakage, and can also detect the purity of high concentration single gas. The sturdy and durable explosion-proof shell and fluorocarbon paint surface treatment process are suitable for various hazardous locations and corrosive environments with strong acids and alkalis. They are resistant to wear and tear and will not fade or paint fall within 10 years.


Technical Parameters:

Detection range: 0-1, 10, 100, 1000, 10000PPM, etc. (customizable range, please contact online customer service for details)

Resolution: 0.1ppm, 0.01PPM, 1PPM (depending on range and sensor)

Display mode: LCD display

Detection method: Diffusion type, flow type, pumping type are optional

Signal output: ① 4-20mA signal: standard 16-bit precision 4-20mA output chip, transmission distance 1Km

② RS485 signal: using standard MODBUS RTU protocol, transmission distance 2Km

                    ③ Voltage signal: 0-5V, 0-10V output, can be set by yourself

                    ④ Pulse signal: also known as frequency signal, adjustable frequency range (optional)

                    ⑤ On-off signal: 2 groups of relays as standard, optional third group of relays, passive contacts of relays

Transmission method: ① Cable transmission: 3 core, 4 core cable, long distance transmission (1-2 km)

                    ② GPRS transmission: can be built-in GPRS module, real-time remote transmission of data without distance limitation (optional)

Receiving equipment: user computer, control alarm, PLC, DCS, etc.

Alarm method: live sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc.

Alarm settings: Standard configuration of two-level alarm, optional three-level alarm; alarm modes can be set: conventional high-low alarm, interval control alarm

Electrical interface: 3/4 ″ NPT internal thread, 1/2 ″ NPT internal thread, and supports 2 electrical connection methods

Housing material: Die-cast aluminum + sandblasted oxidation / fluorocarbon paint, explosion-proof and anti-corrosion

Working power: 24VDC (12 ~ 30VDC)

Dimension and weight: 183 × 143 × 107mm (L × W × H) 1.5Kg (net weight of the instrument)


Precautions:

The gas sensor module is designed with seven pins, which are installed on the sensor socket by plugging and unplugging. To ensure reliable connection, a dedicated jack should be selected. The jack should be arranged according to the corresponding pins, and the jack should be installed vertically and soldered firmly. According to the special requirements of users, it is not necessary to use the pin plug method, but the external lead method, the lead model is ZR-BVR0.75, the wire length generally does not exceed 150mm. In non-explosion-proof places, it can be hot plugged with electricity. For work sites where explosion protection is required, the power to the equipment connected to the sensor must be turned off before installation.

online service